DIGIVAC
™ Models 801W, 810-2 and DVG-6
Model 801W
Wide Range
Low-cost
Varian
replacement
(Mounts in 2.66" panel hole with 3 screws on
1.60" radius)
Model 801
Low-cost
Varian
replacement
(Mounts in 2.66" panel hole with 3 screws on
1.60" radius)
Model 810-2
Low-cost replacement for
Varian
dual controller

(Mounts in 2.66" panel hole with 4 screws on
1.60" radius)
Model
DVG-6 and cDVG-6
Low-cost
Hastings
VT-6 / CVT-16 CVT-26
replacement
with
and without controls Check our prices! Our controllers
much lower in cost than Hastings or Varian. No extra
charge for second 7amp, 230 volt control relay.
Model DVG-4 and cDvg-4
Low-cost
Hastings
VT-4 / CVT-14 CVT-24
replacement
with
and without controls Check our prices! Our controllers
much lower in cost than Hastings or Varian. No extra
charge for second 7amp, 230 volt control relay.
These gauges are designed to fit in the same mounting patterns as the analog gages they replace. (Three bolts for Varian, 4 bolts for Hastings.)
The
801W
is a new Wide-Range Gauge which reads from
Atmosphere to 1 micron
using a low-cost precision inter-changeable thermocouple gauge tube. It is also available with two control outputs. CE rated power supply accepts 115 or 230 vac with no user intervention. Serial port.
801 Micro Ultra Miniature
Vacuum gauge uses on-board Transducer...
yet it has a full-featured microprocessor that can accomplish control and timing functions custom programmed for your application.
The Power supply is 115/230 VAC and CE rated.
On all 801-series gauges, the engraved plastic front panel / lens assembly is mounted on the outside of the panel, and the printed circuit assembly of the gauge is mounted behind. Attractive stainless steel hardware holds the assembly.
The Digivac
810-2
is a new Wide-Range Dual controller
and Gauge which replaces the discontinued Varian 810-2 dual controller. It is superior to the Varian in that it
reads all the way from atmosphere to 1 millitorr.
Easily mounts on enclosure doors - less than 2 " deep!
Has two 240 volt 7 amp Spdt relays, Rs232,
and linearized analog output.
less than half the cost!
Programmed in a High level language Easily Modified.
Highly recommended for new designs!
Gauges work on either 115 or 208/230 VAC 50/60 Hz by terminal strip connection.
Because of their simple, single-circuit board design, the 801/DVG-6 are the most cost effective of the DIGIVAC gauges. They are widely used in new OEM applications such as freeze dryers and vacuum ovens. For the most compact gauge, choose the Model 100P. For information about tubes available, see the Model 100. They are available in all of the standard DIGIVAC Ranges:
0 to 1999 microns 0 to 199.9 microns 0 to 19.99 torr
0 to 760 torr 0 to 199.9 torr 0 to 29.9 in. Hg
0 to 15 Psia 0 to 15 Psig 0 to 150 Psia/Psig
|