Youtube
Show Cart
Your Cart is currently empty.

Model 876

Super Accurate, Dual Sensor Technology, from 1 milliTorr to 760 Torr

Model 876

 

Optional Features and Prices


Options Description Qty Price

Model 876 $682.00

2C The units listed with Control have the ability to turn on an external device via two SPDT external connections allowing controls to be activated at two vacuum set-points. The relays activate at and remain on below the set-points $75.00

5v5T Provides a voltage output proportional to vacuum reading which ranges from 0-5 volts at 1mV per mTorr (1 micron = 1 mV, 5 Torr = 5 Volts) $75.00

Cal Calibration of a Digivac Vacuum gauge against a NIST traceable standard - included on all new gauges $0.00

DS Digivac software which collects and graphs vacuum data on a PC through RS232 or ethernet communications - requires RS232 or Eth option $300.00

mBar Displays vacuum reading in mBar $0.00

24V Unit operates with user supplied 24V DC $0.00

NISTCal Calibration of a Digivac Vacuum gauge against a NIST traceable standard with data $190.00

PrintPlot An optional printer that displays a graphical plotted output when connected to the model 200 $338.00

RS232 Enables vacuum measurement to be transmitted to a PC or another RS232 device through a DB9 female interface. Includes 6 foot DB9 male to female serial cable $75.00

Specifications
Power: AC
Vac Interface: 1/8 inch MNPT
Sensor: 276T
Range: .001-760
Units: Torr

The model 876 produces reliable, consistent accuracy, from 1 milliTorr through 760 Torr (atmospheric pressure.) The 876 leverages dual sensor technology, that offers the unique ability to accurately measure through the entire rough vacuum range of 1 milliTorr through 760 Torr. This instrument builds on the simplicity and success of one of  our best selling vacuum gauges - the Model 801W. This is acheived through a seamless combination of sensing technologies, integrated into a single, easy-to-use, panel-mount unit.  The model 876 is physically equivalent to the Model 801W; however, it adds high accuracy in the Torr ranges.  The 876 adds accuracy approaching that of a capacitance manometer in the range of 10 Torr to 760 Torr/Atmosphere. This unit is also available with RS232 communications, PC software that displays, plots and logs, and an analog recorder output. The 876 is also less sensitive to the composition of gasses, since it uses piezoelectric transducer technology in the 3-760 Torr range.

Last Updated: Saturday, 19 May 2012 08:37
Show Cart