Ai 1400c Controlled Atmosphere Muffle Furnace

Description

Ai 1400C Controlled Atmosphere Muffle Furnace series  feature a chamber with Mitsubishi (Japan) high quality alumina fiber insulation and the famous Kanthal (Sweden) heating elements. A double walled steel internal housing helps minimize heat loss to exterior surface. Furnace operation is controlled by Shimaden (Japan) 40-segment digital controller with built-in RS485 digital communications port and USB adaptor, allowing the user to connect to a PC for remote control and monitoring of the furnace. You can also save or export test results.

The benefits of Ai 1400C Controlled Atmosphere Muffle Furnace

An atmosphere furnace provides the perfect environment for various procedures in many laboratories, providing the controlled temperature and atmosphere specific projects require. The controlled atmosphere is desired to complete tasks that require exact temperatures with no room for error. This is the best way to ensure the successful outcome of your project because it is sealed tightly to ensure the proper environment.

Gases

One of the main components of the atmosphere furnace is the correct mixture of gases. The precise measurement of each gas is essential to the success of your project. You can use a separate chamber to mix the gases, which are then pumped into the furnace chamber where the work will be completed when they are done mixing. It is essential that the separate chamber that holds the gases does not receive any outside air because it could throw off the gas mixture and render your project useless.

Temperature

Proper temperature control is vital to the success of your project as well. Temperatures that are too high or too low will cause problems with the process and could cost your company a significant amount of money. Across International furnaces come with built-in 28-segment PID digital temperature controller for accurate monitoring and consistency.

Features

  • 6x6x6
  • Multiple gas inlets and outlets with stainless steel ball valves. Flow meter to control inbound and outbound gas flows. Outlets can be ignited to burn off gas.
  • Furnace chamber is welded and oil leak tested to ensure air tightness. Furnace door is sealed with high temperature silicon gasket.
  • Built-in stainless steel water-cooling panel protects door sealing gasket when furnace is under heavy use.
  • Microprocessor based self-tuning PID control provides optimum thermal process with minimal overshoot.
  • Multiple atmosphere processes in a single cycle are possible (ex: binder burn out in air and parts sintering under rough vacuum or inert gas environment.)
  • Built-in ammeter and dual voltmeters for easy monitoring and troubleshooting, built-in computer interface.
  • Long life type S thermocouple.
  • ETL and CE certified, standard.

Safety

  • Overheat protection shuts down the furnace if temperature is outside of acceptable range (refer to controller’s manual) or when the thermocouple is broken or malfunctions.
  • Power failure protection resumes furnace operation right after the point of failure when power is reestablished.

 

* Ultimate vacuum level for GCF furnaces is around 100 Pa with all flange connections, and 1000 Pa with hose barb connections. Please keep in mind that our GCF atmosphere furnaces are NOT designed to be vacuum furnaces, the vacuuming part is mainly for users to pre-vac the chamber, before putting in inert or other protective gases.

DigiVac Recommends: Options

Vacuum Pump: Agilent IDP-3Agilent IDP-7, or Agilent DS402

Vacuum Control: Vapor Pressure Controller (VPC)

Electrical requirements  208-240V, 50/60Hz, single phase
Product brochure
 Heating element & thermocouple type
 Silicon carbide (SiC, diameter 12-14mm) / S-type
 Min/max/constant temperatures  Ambient/1400°C/1300°C (depends on gas environment)
 Temperature controller  Shimaden fp93 (Japan) with 4 patterns and
40 segments (ie. 4 x 10 segments or 2 x 20 segments) at +/- 1°C
Maximum heating rate: 15°C per minute
 Furnace cavity  Mitsubishi (Japan) high quality 1600 grade polycrystalline alumina fiber
 Gas inlet/outlet  1/4″ hose barb with 1/4″ BSPT (British Standard Pipe Thread)
 Working environments  Air, N2, Ar, NO2, CO, CO2, He, Ne, etc. (Hydrogen, up to 5%)
 Pressure  Vacuum: 1 torr
Positive: not to exceed 0.02 MPa / 150 torr / 3 psi
 Certification  ETL tested to UL and CSA standards, CE

Maximum Temperatures

 

 
 Air  1400°C
 Helium (He), Neon (Ne), Argon (Ar)
 1400°C
 Nitrogen (N2)  1270°C
 Hydrocarbon gas  1250°C
 Hydrogen (H2) up to 5%  1200°C
 Rough vacuum  1100°C

Size Comparison. Standard size is 6″ x 6″ x 6″. 

 

 
 Nominal vs usable Chamber size (DxWxH)  6x6x6″/4x5x5.5″  12x8x8″/10x7x7.5″

+ $2,000

 16x12x12″/14x11x11.5″

+ $7,000

 Chamber capacity (cu ft)  0.13  0.44  1.33
 Installed heating element  4  8  12
 Maximum output  3 kW  7 kW  13 kW
 Unit/shipping dimensions (WxDxH)  23x28x35″/28x33x45″  26x30x40″/33x34x50″  31x33x44″/43x35x55″
 Unit/shipping weight (Lb)  290/400  450/580  590/720

 

Standard Package

 

 

Part description

 

   

  Quantity

 

 

Part image

 

 GCF1400 controlled atmosphere furnace  1 pc
 Type S thermocouple  1 pc
 Flow meter  1 pc
 Alumina cushion block  1 pc
 Furnace door block  1 pc
 Stainless steel tongs  1 pc
 Thermal gloves  1 pair
 Spare heating element  2 pcs
 Spare fuse 2 pcs
 USB/RS485 computer interface kit  1 set
 Water pump  1 pc
 Furnace operation manual  1 pc
 Shimaden fp93 temperature controller manual & software  1 pc

 

Technical Specifications

 

 Electrical requirements  208-240V, 50/60Hz, single phase
Product brochure
 Heating element & thermocouple type
 Silicon carbide (SiC, diameter 12-14mm) / S-type
 Min/max/constant temperatures  Ambient/1400°C/1300°C (depends on gas environment)
 Temperature controller  Shimaden fp93 (Japan) with 4 patterns and
40 segments (ie. 4 x 10 segments or 2 x 20 segments) at +/- 1°C
Maximum heating rate: 15°C per minute
 Furnace cavity  Mitsubishi (Japan) high quality 1600 grade polycrystalline alumina fiber
 Gas inlet/outlet  1/4″ hose barb with 1/4″ BSPT (British Standard Pipe Thread)
 Working environments  Air, N2, Ar, NO2, CO, CO2, He, Ne, etc. (Hydrogen, up to 5%)
 Pressure  Vacuum: 1 torr
Positive: not to exceed 0.02 MPa / 150 torr / 3 psi
 Certification  ETL tested to UL and CSA standards, CE

 

Maximum Temperatures

 

 
 Air  1400°C
 Helium (He), Neon (Ne), Argon (Ar)
 1400°C
 Nitrogen (N2)  1270°C
 Hydrocarbon gas  1250°C
 Hydrogen (H2) up to 5%  1200°C
 Rough vacuum  1100°C

 


Size Comparison

 

 
 Nominal vs usable Chamber size (DxWxH)  6x6x6″/4x5x5.5″  12x8x8″/10x7x7.5″  16x12x12″/14x11x11.5″
 Chamber capacity (cu ft)  0.13  0.44  1.33
 Installed heating element  4  8  12
 Maximum output  3 kW  7 kW  13 kW
 Unit/shipping dimensions (WxDxH)  23x28x35″/28x33x45″  26x30x40″/33x34x50″  31x33x44″/43x35x55″
 Unit/shipping weight (Lb)  290/400  450/580  590/720

 

Resources

Downloads

UL Cert | Accessories | Tech. Specs

For more documentation, please visit DigiVac’s folder.

Product Inquiry



1700C Controlled Atmosphere Muffle Furnace
Ai 1400C Controlled Atmosphere Muffle Furnace
$10,990.00